|
||||||||||
PREV NEXT | FRAMES NO FRAMES |
Packages that use ModbusException | |
---|---|
net.wimpi.modbus | Provides an object oriented Modbus implementation in Java. |
net.wimpi.modbus.facade | Provides facade pattern implementations. |
net.wimpi.modbus.io | Provides I/O and transport related interfaces and classes. |
Uses of ModbusException in net.wimpi.modbus |
---|
Subclasses of ModbusException in net.wimpi.modbus | |
---|---|
class |
ModbusIOException
Class that implements a ModbusIOException. |
class |
ModbusSlaveException
Class that implements a ModbusSlaveException. |
Uses of ModbusException in net.wimpi.modbus.facade |
---|
Methods in net.wimpi.modbus.facade that throw ModbusException | |
---|---|
BitVector |
ModbusUDPMaster.readCoils(int ref,
int count)
Reads a given number of coil states from the slave. |
BitVector |
ModbusTCPMaster.readCoils(int ref,
int count)
Reads a given number of coil states from the slave. |
BitVector |
ModbusSerialMaster.readCoils(int unitid,
int ref,
int count)
Reads a given number of coil states from the slave. |
BitVector |
ModbusUDPMaster.readInputDiscretes(int ref,
int count)
Reads a given number of input discrete states from the slave. |
BitVector |
ModbusTCPMaster.readInputDiscretes(int ref,
int count)
Reads a given number of input discrete states from the slave. |
BitVector |
ModbusSerialMaster.readInputDiscretes(int unitid,
int ref,
int count)
Reads a given number of input discrete states from the slave. |
InputRegister[] |
ModbusUDPMaster.readInputRegisters(int ref,
int count)
Reads a given number of input registers from the slave. |
InputRegister[] |
ModbusTCPMaster.readInputRegisters(int ref,
int count)
Reads a given number of input registers from the slave. |
InputRegister[] |
ModbusSerialMaster.readInputRegisters(int unitid,
int ref,
int count)
Reads a given number of input registers from the slave. |
Register[] |
ModbusUDPMaster.readMultipleRegisters(int ref,
int count)
Reads a given number of registers from the slave. |
Register[] |
ModbusTCPMaster.readMultipleRegisters(int ref,
int count)
Reads a given number of registers from the slave. |
Register[] |
ModbusSerialMaster.readMultipleRegisters(int unitid,
int ref,
int count)
Reads a given number of registers from the slave. |
boolean |
ModbusUDPMaster.writeCoil(int unitid,
int ref,
boolean state)
Writes a coil state to the slave. |
boolean |
ModbusTCPMaster.writeCoil(int unitid,
int ref,
boolean state)
Writes a coil state to the slave. |
boolean |
ModbusSerialMaster.writeCoil(int unitid,
int ref,
boolean state)
Writes a coil state to the slave. |
void |
ModbusUDPMaster.writeMultipleCoils(int ref,
BitVector coils)
Writes a given number of coil states to the slave. |
void |
ModbusTCPMaster.writeMultipleCoils(int ref,
BitVector coils)
Writes a given number of coil states to the slave. |
void |
ModbusSerialMaster.writeMultipleCoils(int unitid,
int ref,
BitVector coils)
Writes a given number of coil states to the slave. |
void |
ModbusSerialMaster.writeMultipleRegisters(int unitid,
int ref,
Register[] registers)
Writes a number of registers to the slave. |
void |
ModbusUDPMaster.writeMultipleRegisters(int ref,
Register[] registers)
Writes a number of registers to the slave. |
void |
ModbusTCPMaster.writeMultipleRegisters(int ref,
Register[] registers)
Writes a number of registers to the slave. |
void |
ModbusSerialMaster.writeSingleRegister(int unitid,
int ref,
Register register)
Writes a single register to the slave. |
void |
ModbusUDPMaster.writeSingleRegister(int ref,
Register register)
Writes a single register to the slave. |
void |
ModbusTCPMaster.writeSingleRegister(int ref,
Register register)
Writes a single register to the slave. |
Uses of ModbusException in net.wimpi.modbus.io |
---|
Methods in net.wimpi.modbus.io that throw ModbusException | |
---|---|
void |
ModbusUDPTransaction.execute()
|
void |
ModbusTransaction.execute()
Executes this ModbusTransaction. |
void |
ModbusTCPTransaction.execute()
|
void |
ModbusSerialTransaction.execute()
|
|
||||||||||
PREV NEXT | FRAMES NO FRAMES |