java.lang.Objectnet.wimpi.modbus.msg.ModbusMessageImpl
public abstract class ModbusMessageImpl
Abstract class implementing a ModbusMessage. This class provides specialised implementations with the functionality they have in common.
| Constructor Summary | |
|---|---|
ModbusMessageImpl()
|
|
| Method Summary | |
|---|---|
int |
getDataLength()
Returns the length of the data appended after the protocol header. |
int |
getFunctionCode()
Returns the function code of this ModbusMessage as int. The function code is a 1-byte non negative integer value valid in the range of 0-127. Function codes are ordered in conformance classes their values are specified in net.wimpi.modbus.Modbus. |
String |
getHexMessage()
Returns the this message as hexadecimal string. |
int |
getOutputLength()
Returns the number of bytes that will be written by Transportable.writeTo(DataOutput). |
int |
getProtocolID()
Returns the protocol identifier of this ModbusMessage as int. The identifier is a 2-byte (short) non negative integer value valid in the range of 0-65535. |
int |
getTransactionID()
Returns the transaction identifier of this ModbusMessage as int. The identifier is a 2-byte (short) non negative integer value valid in the range of 0-65535. |
int |
getUnitID()
Returns the unit identifier of this ModbusMessage as int. The identifier is a 1-byte non negative integer value valid in the range of 0-255. |
boolean |
isHeadless()
Tests if this message instance is headless. |
abstract void |
readData(DataInput din)
Reads the subclass specific data from the given DataInput instance. |
void |
readFrom(DataInput din)
Reads this Transportable from the given DataInput. |
void |
setDataLength(int length)
Sets the length of the data appended after the protocol header. |
void |
setHeadless()
Sets the flag that marks this ModbusMessage as headless (for serial transport). |
void |
setProtocolID(int pid)
Sets the protocol identifier of this ModbusMessage. |
void |
setTransactionID(int tid)
Sets the transaction identifier of this ModbusMessage. |
void |
setUnitID(int num)
Sets the unit identifier of this ModbusMessage. The identifier should be a 1-byte non negative integer value valid in the range of 0-255. |
abstract void |
writeData(DataOutput dout)
Writes the subclass specific data to the given DataOutput. |
void |
writeTo(DataOutput dout)
Writes this message to the given DataOutput. |
| Methods inherited from class java.lang.Object |
|---|
equals, getClass, hashCode, notify, notifyAll, toString, wait, wait, wait |
| Constructor Detail |
|---|
public ModbusMessageImpl()
| Method Detail |
|---|
public boolean isHeadless()
public void setHeadless()
ModbusMessage
setHeadless in interface ModbusMessagepublic int getTransactionID()
ModbusMessage
getTransactionID in interface ModbusMessagepublic void setTransactionID(int tid)
The identifier should be a 2-byte (short) non negative
integer value valid in the range of 0-65535.
tid - the transaction identifier as int.public int getProtocolID()
ModbusMessage
getProtocolID in interface ModbusMessagepublic void setProtocolID(int pid)
The identifier should be a 2-byte (short) non negative
integer value valid in the range of 0-65535.
pid - the protocol identifier as int.public int getDataLength()
ModbusMessage
getDataLength in interface ModbusMessagepublic void setDataLength(int length)
Note that this library, a bit in contrast to the specification, counts the unit identifier and the function code to the header, because it is part of each and every message. Thus this message will append two (2) to the passed in integer value.
length - the data length as int.public int getUnitID()
ModbusMessage
getUnitID in interface ModbusMessagepublic void setUnitID(int num)
num - the unit identifier number to be set.public int getFunctionCode()
ModbusMessage
getFunctionCode in interface ModbusMessageModbus
public void writeTo(DataOutput dout)
throws IOException
writeTo in interface Transportabledout - a DataOutput instance.
IOException - if an I/O related error occurs.
public abstract void writeData(DataOutput dout)
throws IOException
dout - the DataOutput to be written to.
IOException - if an I/O related error occurs.
public void readFrom(DataInput din)
throws IOException
Transportable
readFrom in interface Transportabledin - the DataInput to read from.
IOException - if an I/O error occurs or the data
is invalid.
public abstract void readData(DataInput din)
throws IOException
din - the DataInput to read from.
IOException - if an I/O related error occurs.public int getOutputLength()
TransportableTransportable.writeTo(DataOutput).
getOutputLength in interface Transportablepublic String getHexMessage()
getHexMessage in interface ModbusMessage
|
||||||||||